Search Article 
  
 Advanced search 
  
 
About us - Editorial board - Browse articles - Submit article - Instructions - Subscribe - Advertise - Contacts - Login 
  Users Online: 837 Home Print this page Email this page Small font sizeDefault font sizeIncrease font size   

ORIGINAL ARTICLE
Year : 2015  |  Volume : 5  |  Issue : 1  |  Page : 39

Novel Method to Improve Radiologist Agreement in Interpretation of Serial Chest Radiographs in the ICU


1 Department of Imaging, University of Toronto, Toronto, School of Nursing, Queen's University, Kingston, Ontario, Canada
2 Department of Diagnostic Radiology, School of Nursing, Queen's University, Kingston, Ontario, Canada
3 Department of Anesthesiology and Perioperative Medicine, School of Nursing, Queen's University, Kingston, Ontario, Canada

Correspondence Address:
Dr. Donald Soboleski
Department of Diagnostic Radiology, Queen's University, Kingston, Ontario - K7L 2V7
Canada
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2156-7514.161848

Rights and Permissions

Objectives: To determine whether a novel method and device, called a variable attenuation plate (VAP), which equalizes chest radiographic appearance and allows for synchronization of manual image windowing with comparison studies, would improve consistency in interpretation. Materials and Methods: Research ethics board approved the prospective cohort pilot study, which included 50 patients in the intensive care unit (ICU) undergoing two serial chest radiographs with a VAP placed on each one of them. The VAP allowed for equalization of density and contrast between the patients' serial chest radiographs. Three radiologists interpreted all the studies with and without the use of VAP. Kappa and percent agreement was used to calculate agreement between radiologists' interpretations with and without the plate. Results: Radiologist agreement was substantially higher with the VAP method, as compared to that with the non-VAP method. Kappa values between Radiologists A and B, A and C, and B and C were 46%, 55%, and 51%, respectively, which improved to 73%, 81%, and 66%, respectively, with the use of VAP. Discrepant report impressions (i.e., one radiologist's impression of unchanged versus one or both of the other radiologists stating improved or worsened in their impression) ranged from 24 to 28.6% without the use of VAP and from 10 to 16% with the use of VAP (χ2 = 7.454, P < 0.01). Opposing views (i.e., one radiologist's impression of improved and one of the others stating disease progression or vice versa) were reported in 7 (12%) cases in the non-VAP group and 4 (7%) cases in the VAP group (χ2 = 0.85, P = 0.54). Conclusion: Numerous factors play a role in image acquisition and image quality, which can contribute to poor consistency and reliability of portable chest radiographic interpretations. Radiologists' agreement of image interpretation can be improved by use of a novel method consisting of a VAP and associated software and has the potential to improve patient care.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed35568    
    Printed6    
    Emailed0    
    PDF Downloaded124    
    Comments [Add]    

Recommend this journal